Skip to content

Dashboard

This page is the Digital Twin workspace: the 3D view, side panel, Agents, and console.

Control Description
Health Twin / Console / Agents
System Context scanner_id / mode
Workspace Switch rooms with ⌘K / Ctrl+K
Settings Models, runtime, key, devices, updates. Settings.
Menu Workspace-specific

Side panel

Tab Contents
Telemetry Thermal, magnetic / \(B_0\), EMI, RF
Agents Chat with the twin (needs a Google API key)
Forecast Horizon, setpoint, heating rate, PINN
Notes Messages from the twin
Raw sensors On-demand sensor batch
View / CAD Explode, wireframe, temperature map

Width, collapse, and Telemetry vs Agents persist when Settings → Workspace says so.

Provenance

Source Meaning
measured Sensor
estimated Twin estimate
predicted Forecast only
nominal Design value

Confidence is shown when the twin sends it. Units stay on the number.

Viewport and tool rail

The scene uses the active scanner model from Settings (bundled or imported). The rail picks a mode:

Tool Purpose
Magnet CAD / thermal
EMI EMI context
RF RF noise context
Camera Webcam and head pose
Gradient Gradient emphasis

Rail position is remembered.

Camera

Select Camera on the rail. Allow the camera when macOS or Windows asks.

The live picture should appear first. Face tracking loads next (bundled WASM in the app; models download once from Google). You can set a reference pose, export a JSON/CSV motion log, and Share with agent.

See Settings if permission is denied.

Live dashboard

Open live dashboard overlays magnet temperature, Johnson noise, and the EMI sensor spectrum.

In simulation, Johnson noise is drawn from temperature (\(\sqrt{T}\)), and the EMI plot shows narrow interference spikes over a white-noise floor in arbitrary units on a logarithmic 1–100 kHz axis. That EMI display is illustrative, not a phantom signal or a calibrated analyzer.

In hardware, the dashboard and Telemetry panel wait until a recent measured sample arrives. Configure sensors and Check connections open Settings → Devices. The connection guide matches Device link. The header, floating navigation, and terminal stay in place.

A board may publish only some families. Connected channels render; the others keep their own copy:

Card Hardware copy
Magnet temperature Plot when magnet temperature is received; otherwise “Temperature sensor not connected”
Johnson noise “Johnson noise is simulated only; it is not measured in hardware”
EMI RMS stamp when voltage_rms is received, with no spectrum; otherwise “EMI sensor not connected”

Telemetry cards that have no usable values say No usable … measurements. Twin Notes list each family as received, not connected, reported missing, invalid, or stale. Missing or omitted sensors are never drawn as zero. Hardware does not synthesize an EMI spectrum from RMS. Reception uses a 30-second freshness window; API connectivity alone does not count as sensor data.

Agents

Feature Detail
Markdown Assistant replies
Model Gemini models you configured in Settings
Attachments Images in the composer
Forecast plots Inline when a tool returns a plot
Head motion One-click share from the camera HUD

Console

Tab Contents
Logging Timestamped system events
Terminal Real $SHELL on desktop. In the browser: help, clear, status.

Launch intro

Plays once per install (desktop) or once per browser tab. Replay with ?replayIntro=1. Honors reduced motion.

Out of scope

  • Shim / gradient / safety commands on the Twin API
  • Treating predicted values as live measurements
  • Opening the Red Pitaya socket from the UI (use Imaging Console + Python)